English  |  正體中文  |  简体中文  |  Items with full text/Total items : 25835/26429 (98%)
Visitors : 8223101      Online Users : 300
RC Version 7.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
Scope Tips:
  • please add "double quotation mark" for query phrases to get precise results
  • please goto advance search for comprehansive author search
  • Adv. Search
    HomeLoginUploadHelpAboutAdminister Goto mobile version


    Please use this identifier to cite or link to this item: http://ir.lib.ksu.edu.tw/handle/987654321/8610


    Title: 矽基太陽電池之系統發電性能評估
    System Performance Evaluation of Silicon-based Solar cell
    Authors: 蔡知達(CHIH-TATSAI)
    嚴坤龍(KUN-LUNG YEN)
    白明憲(MING-SING R. BAI)
    陳定鼎(TING-TING CHEN)
    Keywords: 太陽電池
    系統性能評估
    多晶矽
    HIT
    非晶矽
    Solar Cell
    Performance Evaluation
    Poly Silicon (p-Si)
    HIT
    Amorphous Silicon (a-Si)
    Date: 2008-09-05
    Issue Date: 2010-02-22 14:43:44 (UTC+8)
    Abstract: 為探討矽基太陽電池(Silicon-based Solar Cell)之系統發
    電性能,本文分別選用非晶矽(Amorphous, a-Si)、HIT( Hetero
    junction with Intrinsic Thin Layer)與多晶矽(Poly Silicon, p-Si)
    等三種型式太陽電池,進行系統發電性能評估,系統型式為
    併聯型(Grid-connected System)發電系統,模組設置方位角為
    正南,傾斜角為10 度;依97 年1 月至6 月的統計結果,每
    kWp 日平均發電量分別為3.27、2.82 與3 (kWh/d /kWp),整
    體系統效率為5.82、13.51 與11.97%,以非晶矽系統日平均
    發電量較高,但因其模組效率較低,在同系統容量條件下,
    設置面積為HIT 模組的2.66 倍,為多晶矽模組的2.23 倍。
    The photovoltaic system performance evaluation of
    silicon- based solar cells is presented in this paper. The
    Amorphous Silicon (a-Si)、Hetero junction with Intrinsic Thin
    Layer (HIT) and Poly Silicon (p-Si) are three kinds of solar cells
    assessed in this study. Three photovoltaic systems are the
    grid-connected type and installed at due south and inclined at 10o
    .
    System performances were monitored from January to June 2007.
    The daily mean yields (DMY) of a-Si, HIT and p-Si systems
    were 3.27, 2.82 and 3 (kWh/d/kWp), and the system efficiency
    were 5.82, 13.51 and 11.97%. The DMY of a-Si system is higher
    than HIT and p-Si, but a-Si cell conversion efficiency is lower
    than other cells. Therefore, installation array area of a-Si is 2.66
    times of HIT and 2.23 times of p-Si at the 1kWp system capacity
    condition.
    Relation: 台灣電子電力研討會暨展覽會
    Appears in Collections:[電機工程系所 ] 2008第七屆台灣電力電子研討會暨展覽會

    Files in This Item:

    File Description SizeFormat
    矽基太陽電池之系統發電性能評估.pdf1424KbAdobe PDF21View/Open


    All items in KSUIR are protected by copyright, with all rights reserved.


    本網站之所有圖文內容授權為崑山科技大學圖書資訊館所有,請勿任意轉載或擷取使用。
    ©Kun Shan University Library and Information Center
    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - Feedback