    Title: 電化學處理技術應用於水中五氯酚之移除
    其他題名: Removal of Pentachlorophenol in Water by Electrochemical Treatment Process
    Authors: 王志偉
    Jr-Wei Wang
    指導教授: 吳庭年
    Keywords: 五氯酚
    電化學
    氧化還原
    Pentachlorophenol
    Electrochemical
    redox
    Date: 2008-09-09
    Issue Date: 2010-01-18 17:38:15 (UTC+8)
    Abstract: 本論文主要以電化學處理技術偵測氯酚化合物與去除水中五氯酚,採用50 mL的非分離式電解槽作為反應器,電解電壓由電化分析儀控制, 連接三個電極:輔助電極為白金絲、參考電極為Ag/AgCl 電極,工作電極為白金電極,實驗操作採用定電壓電解,實驗中電極上電流的量測使用6位半精密高階數位電表。
    在偵測污染物的實驗之中,使用0.3 V/s做為線性掃描伏安法的最佳掃描速度,利用循環伏安法掃描可測得4-氯酚、2,4-二氯酚及五氯酚水溶液中氧化與還原波峰,4-氯酚的氧化與還原電位為1.218與 -0.460 V、2,4-二氯酚之氧化與還原電位為1.128與 -0.448 V及五氯酚之氧化還原電位為1.037與-0.473 V。氯酚化合物以線性掃描伏安法進行分析測定,其濃度的線性範圍分別為︰4-氯酚為0.2~1 mg/L、2,4-二氯酚為0.3~2 mg/L及五氯酚為0.1~4 mg/L。由本研究實驗證實應用電化學分析儀來測定微量的氯酚化合物是可行的,且為一種快速的檢測方法。
    以電解質1.00 M KI降解五氯酚實驗組中,在電解電壓500 mV (vs. Ag/AgCl)下進行電解實驗,五氯酚完全的被去除;但在相同的電解條件中,使用電極質1.00 M KCl與Na2SO4對於五氯酚並沒有達到完成去除情形,可能的原因為電解質KI電解後產生I3-與I-氧化還原媒子反應,使五氯酚進行逐步脫氯反應。使用電壓-1200 mV(vs. Ag/AgCl)之電解實驗,五氯酚去除率亦達99%,因電解水生成氫原子會與吸附電極上之五氯酚進行脫氯反應,同時發現脫氯反應與五氯酚降解反應是同步在進行的,即吸附的五氯酚完成脫氯反應後,才會進行下一個五氯酚分子的脫氯反應。
    以KCl為電解質之實驗組降解五氯酚之實驗中得知,以使用電解電壓-1.50 V(vs. Ag/AgCl),電解質為0.50 M KCl 為最佳電解條件,電解120 min 後五氯酚可達到99 %以上的去除率,在相同的電解條件中使用電解質NaNO3與CaCO3其五氯酚沒有任何去除效果。在pH 值3.86之條件下,120min 對五氯酚的去除率可達99 %以上;而pH 值9.97 ,電解120 min 對五氯酚的去除率為88%,由此可見,在低pH 值條件下對五氯酚去除效率較佳。在本研究實驗中,五氯酚降解後生成之物種經由GC/MS鑑定後出現三種中間產物分別為1﹐2-二氯環己烷、順2-氯環己醇及3-HEXEN-1-YNE。
    因此,在適當的操作條件下,可利用電化學技術使水中五氯酚有效地脫氯降解。
    This study addressed the application of electrochemical technology on the detection of chlorophenols and the removal of pentachlorophenol in water. The reactor used in this study is a 50 mL double-jacketed glassware , which is established a Pt electrode as working electrode, a Pt wire as counter electrode, and an Ag/AgCl electrode as reference electrode. The electrochemical analyzer is employed to precisely control a constant potential during the experiments, and the currency passing through the electrodes in the reactor was recorded by the 61/2 multimeter.
    In the detection experiments, the scan rate is set at 0.3 V/s under the analysis of linear sweep voltammetry (LSV). On the cyclic voltammetry (CV) plot, each pair of clear redox peaks was observed for 4-chlorophenol (4-CP), 2,4-dichlorophenol (2,4-DCP), and penta- chlorophenol (PCP). The potentials of the redox pairs were 1.218 and -0.460 V for 4-CP, 1.128 and -0.448 V for 2,4-DCP, and 1.037 and -0.473 V for PCP. Based on the liner relationship between the concentrations of chlorophenols and the corresponding peak current, the suitable quantification ranges were 0.2~1 mg/L for 4-CP, 0.3~2 mg/L for 2,4-DCP, and 0.1~4 mg/L for PCP by the LSV analysis. The detection experiments demonstrated a quick measurement method to quantify the trace levels of chlorophenols in water by the electrochemical analyzer.
    As using 1.00 M KI as electrolyte in the degradation experiments, a complete removal of PCP was achieved by the electrolysis at 500 mV. However, the same controls of degradation experiments did not result in a similar result as using 1.00 M KCl or Na2SO4. A possible contribution is ascribed to the formation of the redox couple I3-/I-, which might play the role of mediator to initiate indirect oxidation. On the contrary, PCP can be completely removed for 1.00 M KI, KCl, or Na2SO4 by the electrolysis at -1200 mV. The possible mechanism is that the forming H atoms from water electrolysis might dechlorinate the adsorbed PCP on the electrode surface. Thus, the degradation of PCP synchronized with the dechlorination of PCP.
    As using 0.50 M KCl as electrolyte in the degradation experiments, a complete removal of PCP was achieved by the electrolysis at -1500 mV. The same controls of experiment conditions did not result in a similar result as using NaNO3 or CaCO3. The removal of PCP is only 88% under the initial pH 9.97, while the removal efficiency is over 99% under the initial pH 3.86. As a consequence, the strong basic condition of initial pH is not favorable for the electrochemical degradation of PCP. Based on the analysis of GC/MS, the intermediates of PCP degradation are determined as 1,2-dichloro-cyclohexane, trans-2-chloro-cyclohexamol, and 3-hexen- 1-yne. Accordingly, PCP can be successfully dechlorinated by a proper control of electrochemical treatment process.
    Appears in Collections:[環境工程系所] 博碩士論文

    Files in This Item:

    File Description SizeFormat
    0909200815315600_摘要.pdf65KbAdobe PDF609View/Open
    0909200815315600_目次.pdf66KbAdobe PDF561View/Open
    ksu-97-G940N009-1.pdf1652KbAdobe PDF273View/Open